The run show poe power command displays the PoE power status.
...
On AS4610-30P, AS4610-54P, AS4630-54PE, AS4625-54P and AS4630-54NPE,
- If Power Management mode is dynamic, total power allocated is about the same value as realtime consumption.
- But if Power Management mode is static, total power allocated is usually larger than realtime consumption.
...
On AS4610-30P, AS4610-54P, AS4630-54PE, AS4625-54P and , AS4630-54NPE and S5810-48TS-P:
Code Block |
---|
admin@XorPlus# run show poe power Total power allocated RealTime consumption Power available Power Mode PSU1 Status PSU2 Status ------------------------------------------------------------------------------------------------------------------------ 2.20W 2.20W 675.00W redundant Powered on Present but powered off |
...
Item | Description |
Total power allocated | Total allocated max power for all ports. |
RealTime consumption | The actual consumption power of all ports on AS4610-30P, AS4610-54P, AS4630-54PE, AS4625-54P and AS4630-54NPE. |
Power available | The max limit power value of PSE on AS4610-30P, AS4610-54P, AS4630-54PE, AS4625-54P and AS4630-54NPE.
|
Consumption Power | The actual power consumed by all ports. |
Calculated Power | The sum of all ports power, allocated as defined by IEEE standard 802.3af-2003, or actually consumed. |
Available Power | The max limit power value of PSE.
|
Power Mode | Redundant or aggressive based on set. |
PSU1 Status | Status of PSU1. |
PSU2 Status | Status of PSU2. |
...