NOTE:

1. The last two ports are 10G-Base-KR ports which can be configured as two 10G SFP+ ports on the front panel or two 10G-KR ports linked to CPU. By default, 10G-Base-KR ports are disabled. For details please refer to document 10G-Base-KR Interface Configuration.

2. On N8550-48B8C switch, when the 10G-Base-KR ports are enabled as either front panel ports or management ports, xe-1.       /1/8 port is not allowed to be split into four Gigabit Ethernet interfaces.

3. The first 48 ports are grouped as shown in the following table, four ports form a group.

Group

Ports

1

Port1, Port2, Port3, Port6

2

Port4, Port5, Port7, Port9

3

Port8, Port10, Port11, Port12

4

Port13, Port14, Port15, Port18

5

Port16, Port17, Port19, Port21

6

Port20, Port22, Port23, Port24

7

Port25, Port26, Port27, Port30

8

Port28, Port29, Port31, Port33

9

Port32, Port34, Port35, Port36

10

Port37, Port38, Port39, Port42

11

Port40, Port41, Port43, Port45

12

Port44, Port46, Port47, Port48

2.       For the first 48 portsWhen configuring the rate, the transmission rates of optical modules inserted in the supported port rates are 25 Gbit/s, 10 Gbit/s, and 1 Gbit/s. The four ports of a group needs to be the same, and the configured port speed must be the same too, that is to say,

  •    when inserting an optical module to the switch port, the transmission rates of the optical modules should be the same in a group.
  •    you should manually configure the port speed by using the set interface gigabit-ethernet speed command before inserting an optical module, and the port speed of the four ports in the same group should be configured together and with the same value.

3.       The last two ports are 10G-Base-KR ports which can be configured as two 10G SFP+ ports on the front panel or two 10G-KR ports linked to CPU. By default, 10G-Base-KR ports are disabled. For details please refer to document 10G-Base-KR Interface Configuration.

4.       On N8550-48B8C switch, when the 10G-Base-KR ports are enabled as either front panel ports or management ports, xe-1/1/8 port is not allowed to be split into four Gigabit Ethernet interfaces.can be configured with the same port rate or different rate. When configuring at different port rates, 10G and 1G can coexist, but 25G cannot coexist with 10G or 1G. The following table gives several cases of speed setting for the group of ports.



Port1Port2Port3Port6

Allowed or not allowed

case #110 G10G10G10G
case #21G1G1G1G
case #325G25G25G25G
case #41G10G1G10G
case #525G1G25G25G×
case #625G10G25G10G×
case #725G1G10G25G×


Mapping between physical ports, interface names and interface support speed are in the following table.

...