CDR Function Configuration
Clock and Data Recovery (CDR) is a process that is dependent upon a clock signal synchronous with the data flow. When a data flow arrives at the receiver, it is sent without additional clocking information, the receiver generates a clock from an approximate frequency reference, and then phase-aligns the clock to the transitions in the data flow with a phase-locked loop (PLL). Data distortion, noise, and jitter on the incoming data can be reduced if the CDR technology is used for data recovery from the transmission channel.
NOTE:
|
Procedure
Use the following command to disable or enable the CDR function.
set interface gigabit-ethernet <interface-name> cdr [true | false]
The default setting is true. The command takes effect immediately after committing.
Configuration Example
Enable the CDR function on interface te-1/1/49.
admin@Xorplus# set interface gigabit-ethernet te-1/1/49 cdr true admin@Xorplus# commit
Disable the CDR function on interface te-1/1/49.
admin@Xorplus# set interface gigabit-ethernet te-1/1/49 cdr false admin@Xorplus# commit