Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.


...

The run show poe power command displays the PoE power status.

...

On AS4610-30P, AS4610-54P, AS4630-54PE, AS4625-54P and AS4630-54NPE,

  • If Power Management mode is dynamic, total power allocated is about the same value as realtime consumption.
  • But if Power Management mode  is static, total power allocated is usually larger than realtime consumption.

...

On AS4610-30P, AS4610-54P, AS4630-54PE, AS4625-54P, AS4630-54NPE, S5860-24XB-U, S5810-48TS-P, S5860-24MG-U and S5860U, S5860-48XMG-U and S3410C-8TMS-P:

Code Block
admin@XorPlus# run show poe power
Total power allocated           RealTime consumption     Power available   Power Mode    PSU1 Status    PSU2 Status 
------------------------------------------------------------------------------------------------------------------------
2.20W                           2.20W                     675.00W         redundant       Powered on          Present but powered off

...

Item

Description

Total power allocated

Total allocated max power for all ports.

RealTime consumption

The actual consumption power of all ports.

Power available

The max limit power value of PSE.

Consumption Power

The actual power consumed by all ports.

Calculated Power

The sum of all ports power, allocated as defined by IEEE standard 802.3af-2003, or actually consumed.

Available Power

The max limit power value of PSE.

Power Mode

Redundant or aggressive based on set.

PSU1 Status

Status of PSU1.

PSU2 Status

Status of PSU2.

...