set interface ethernet-switching-options analyzer erspan output vrf
The set interface ethernet-switching-options analyzer erspan output vrf command configures the VRF of the ERSPAN GRE tunnel of destination interface. Note that you have to ensure the remote data monitoring server is route reachable in the VRF.
The delete interface ethernet-switching-options analyzer erspan output vrf command deletes the configuration.
Command Syntax
set interface ethernet-switching-options analyzer <mirror-name> erspan output vrf <vrf-name>
Parameters
Parameter | Description |
analyzer <mirror-name> | Specifies a name of the ERSPN. The value is a string. |
vrf <vrf-name> | Specifies the VRF name of the GRE tunnel for ERSPAN. |
Example
- Configure VRF of the GRE tunnel for ERSPAN.
admin@Xorplus# set interface ethernet-switching-options analyzer 111 erspan output vrf vrf1 admin@Xorplus# commit