run show poe interface
The run show poe interface command displays the PoE status of all the ports or on a specific ethernet port.
Command Sytax
run show poe interface {<port-id> | all}
Parameter
Parameter | Description |
interface {<port-id> | all} | Specifies interface ID. The value could be ge-1/1/1 to ge-1/1/48, all indicates to display PoE status of all the ports. |
Example
• This example is to show poe interface of ge-1/1/1:
admin@XorPlus# run show poe interface ge-1/1/1 Port Status Consume Reserved Pair PD_Type PD-Class Detection_Type -------------------------------------------------------------------------------- ge-1/1/1 Searching 2.80W 16.20W A IEEE 2 IEEE 802.3af 4-Point
• This example is to show poe interface of all the ports:
admin@XorPlus# run show poe interface all Port Status Consume Reserved Pair PD_Type PD-Class Detection_Type ---------------------------------------------------------------------------- ge-1/1/1 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/2 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/3 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/4 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/5 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/6 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/7 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/8 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/9 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/10 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/11 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/12 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/13 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/14 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/15 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/16 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/17 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/18 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/19 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/20 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/21 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/22 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/23 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/24 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/25 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/26 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/27 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/28 Delivering 1.10W 16.2W A IEEE 2 IEEE 802.3af 4-Point ge-1/1/29 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/30 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/31 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/32 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/33 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/34 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/35 Delivering 1.30W 16.2W A IEEE 2 IEEE 802.3af 4-Point ge-1/1/36 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/37 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/38 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/39 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/40 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/41 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/42 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/43 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/44 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/45 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/46 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/47 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point ge-1/1/48 Searching 0.00W 0.00W A None 4 IEEE 802.3af 4-Point
Table 1 Description of the run show poe interface all command output of AS4610-30P, AS4610-54P
Item | Description |
Port | Port ID. |
Status | Indicates that PoE function status, the value could be Disabled, Searching, Delivering, Test, Requesting and Fault. |
Consume | Indicates the power consumption of port. |
Reserved | Indicates the power allocated.
|
Pair | Indicates PoE pair mode. A: signal, deliver power with data transmit cable. B: spare, deliver power with spare cable. |
PD_Type | Indicates powered device type, the value could be None, IEEE, Pre-Standard and Extended. |
PD_Class | Indicates the PD class, the value could be 1, 2, 3, 4. |
Detection_Type | Indicates PoE detection type, the value could be: no detection Legacy Capacitive Detection only IEEE 802.3af 4-Point Detection only IEEE 802.3af 4-Point followed by Legacy IEEE 802.3af 2-Point Detection IEEE 802.3af 2-Point followed by Legacy |
Copyright © 2024 Pica8 Inc. All Rights Reserved.