N3248PXE-ON/N3248X-ON Switch


System LED Definition

Feature

Detailed Description

Comment

Platform Stacking LED

Not supported.

At front

System Status LED

(Bi-color LED)

  •    Solid Green – all functions are normal
  •    Flashing Green with 2 sec on and 1 sec off – Booting
  •    Solid Amber – Major Fault
  •    Flashing Amber with 2 sec on and 1 sec off – Minor Fault

At front

Power Status LED

(Bi-color LED)

  •    Solid Green – Normal
  •    Solid Amber – POST in progress
  •    Flashing Amber with 2 sec on and 1 sec off – PSU fault
  •    Off – No power

At front

FAN Status LED

(Bi-color LED)

  •    Solid Green – all functions are normal
  •    Solid Amber – Fan tray fault

At front

System Beacon LED

  •   Off – Idle
  •   Flashing Blue with 1 sec on and 1 sec off – (SID in Dell parlance)

At front

7-DIGIT Stack LED

Not in use.

At front

Port LED Definition

1G/2.5G/5G/10G copper port LEDs:

Feature

Detailed Description

Link/SPD LED

(Left bi-color LED)

  •    Solid Green – Link at 10GBase-T (Max)
  •    Solid Amber – Link at 10/100/1000MBase-T or 2.5/5GBase-T
  •    Off – No Link

POE/ACT LED

(Right bi-color LED)

(On N3248PXE-ON)

  •    Blinking Green (~30ms) – Activity, PoE Power Off (Activity for Non-P)
  •    Blinking Amber (~30ms) – Activity, PoE Power On
  •    Solid Amber – No Activity, PoE Power On
  •    Off –No Activity, PoE Power Off


25GbE SFP28 Port LEDs:

Feature

Detailed Description

Link/SPD LED

(Left bi-color LED)

  •    Off – No Link
  •    Solid Green –Link at 25GE Speed
  •    Solid Amber –Link at lower than 25GE Speed

ACT LED

(Right bi-color LED)

  •    Off – No Activity
  •    Blinking green (~30ms) – Activity

 

Stacking (QSFP28) Port LEDs:

Feature

Detailed Description

LINK/ACT LED

(Bi-color LED)

1st LED: Green/Amber

  •    Solid Green = Port linked operating at max port speed,

i.e. running 100GbE on QSFP28 port. Green (Luminance at 1.5ft = 45+5 cd/m2)

  •    Flash Green (~30ms) = Port Activity operating at max port speed,

i.e. running 100GbE on QSFP28 port. Green (Luminance at 1.5ft = 45+5 cd/m2)

  •    Solid Amber = Port linked operating at lower speed,

i.e. running 40GbE or 25GbE or 10GbE on QSFP28 port. Amber (Luminance at 1.5ft = 45+5 cd/m2)

  •    Flashing Amber (~30ms) =Port Activity operating at lower speed,

i.e. running 40GbE or 25GbE or 10GbE on QSFP28 port. Amber (Luminance at 1.5ft = 45+5 cd/m2)

  •    Off = No link
  •    Flashing Amber with 1 sec on and 1 sec off – Port Beacon. Amber (Luminance at 1.5ft = 180+10 cd/m2)


All four LEDs shall be used when 4x25GbE mode or 4x10GbE mode is running on QSFP28 port.

  •    Solid Green = 4x25GbE Link on QSFP28 port. Green (Luminance at 1.5ft = 45+5 cd/m2)
  •    Solid Amber = 4x10GbE Link on QSFP28 port. Amber (Luminance at 1.5ft = 45+5 cd/m2)
  •    Flashing (~30ms) Green = 4x25GbE Activity on QSFP28 port.
  •    Green (Luminance at 1.5ft = 45+5 cd/m2)
  •    Flashing (~30ms) Amber = 4x10GbE Activity on QSFP28 port.
  •    Amber (Luminance at 1.5ft = 45+5cd/m2)
  •    Off = No link
  •    Flashing Amber with 1 sec on and 1 sec off – Port Beacon. Amber (Luminance at 1.5ft = 180+10 cd/m2)


OOB Ethernet Port LEDs:

Feature

Detailed Description

Link/SPD LED

(Left bi-color LED)

  •    Off – No Link
  •    Solid green – Link on 1000Base-T
  •    Solid Amber – Link on 10/100MBase-T

ACT LED

(Right single color LED)

  •    Off – No Link
  •    Blinking Green (~30ms) – Activity


Console port LEDs:

Feature

Detailed Description

Link/SPD LED

(Left bi-color LED)

  •    Off – No Link
  •    Solid green – Link