Configuring EFM OAM

Configuration Notes and Constraints

When configuring EFM OAM, pay attention to the following notes:

  • An EFM connection cannot be established between two EFM OAM entities that are both in passive mode.

  • Only the active mode end can run commands ethernet-oam remote-loopback start interface <interface-name> or ethernet-oam remote-loopback stop interface <interface-name> to start | stop EFM OAM remote loopback tests.

  • Before starting the EFM OAM remote loopback tests, make sure:

    • The EFM OAM connection has been established successfully.

    • Users have to configure command set protocols ethernet-oam interface <interface-name> remote-loopback supported on the responding end to enable reactions to loopback control OAMPDUs from peers.

  • Remote loopback cannot be configured on the same port as the loopback of the physical port.

Configuring EFM OAM

Step 1      Enable EFM OAM function on both end of the link.

         set protocols ethernet-oam interface <interface-name> enable <true | false>

Step 2      Configure the EFM mode for this Ethernet port. By default, the EFM OAM interface works in active mode.

         set protocols ethernet-oam interface <interface-name> mode <active | passive>

Step 3      Enable reactions to loopback control OAMPDUs from peers.

         set protocols ethernet-oam interface <interface-name> remote-loopback supported

Step 4      (Optional) Configure EFM OAM timeout values.

         set protocols ethernet-oam interface <interface-name> remote-loopback timeout <loopback-timeout>

         set protocols ethernet-oam interface <interface-name> timeout <oam-timeout>

Step 5      Enable EFM OAM remote loopback tests on the specified port.

NOTEs:

  • The commands ethernet-oam remote-loopback start interface and ethernet-oam remote-loopback stop interface are operational mode commands which should be executed under the prompt “admin@PICOS>”.

  • Only the active mode end can run commands ethernet-oam remote-loopback start interface <interface-name> or ethernet-oam remote-loopback stop interface <interface-name> to start| stop EFM OAM remote loopback tests.

  • Before starting the EFM OAM remote loopback tests, make sure:

    • The EFM OAM connection has been established successfully.

    • Users have to configure command set protocols ethernet-oam interface <interface-name> remote-loopback supported on the responding end to enable reactions to loopback control OAMPDUs from peers.

  • It is not allowed to modify EFM OAM mode when remote loopback function is implemented.

         ethernet-oam remote-loopback start interface <interface-name>

Step 6      Stop EFM OAM remote loopback tests on the specified port.

         ethernet-oam remote-loopback stop interface <interface-name>

Step 7      Commit the configuration.

         commit

Step 8      View EFM OAM configuration information, session status and interface statistics.

         run show ethernet-oam [interface <interface-name>]

         run show ethernet-oam statistics [interface <interface-name>]

Example for Configuring EFM OAM

Networking Requirements

Figure 1.     EFM OAM Configuration Example

As shown in Figure 1, the link between Switch C to Switch A is a newly deployed network. The administrator hopes to achieve the following network management:

  • Test network connectivity and quality before enabling the new network.

  • Dynamically monitor the link quality after the link is properly enabled.

Follow the configuration roadmap below to configure EFM function:

1. Configure EFM basic functions on Switch A and Switch C devices to achieve automatic detection of link connectivity.

2. Configure EFM remote loopback on Switch A and Switch C to conduct link connectivity and performance testing.

Procedure

Step 1      Configure EFM basic function.

a)  Enable EFM OAM function on interface ge-1/1/1 on Switch A.

admin@SwitchA# set protocols ethernet-oam interface ge-1/1/1 enable true

b) Configure the EFM OAM mode for this Ethernet port.

admin@SwitchA# set protocols ethernet-oam interface ge-1/1/1 mode active admin@SwitchA# commit

         c) Enable EFM OAM function on interface ge-1/1/1 on Switch C.

admin@SwitchC# set protocols ethernet-oam interface ge-1/1/1 enable true

d) Configure the mode of EFM OAM mode for this Ethernet port.

         e) Verify the Configuration.

If the EFM configurations of Switch A and Switch C are correct, a connection will be established between them after successful negotiation in the Discovery phase. Run the command run show ethernet-oam on Switch A or Switch C, you can see that the EFM OAM protocol status of interface ge-1/1/1 is SEND_ANY.

Step 2      Enable remote loopback.

a) Enable reactions to loopback control OAMPDUs from peers on Switch C.

b) Start EFM OAM remote loopback tests on interface ge-1/1/1 on Switch A.

NOTEs:

  • The commands ethernet-oam remote-loopback start interface and ethernet-oam remote-loopback stop interface are operational mode commands which should be executed under the prompt “admin@PICOS>”.

  • Before starting the EFM OAM remote loopback tests:

    • The EFM OAM connection has been established successfully.

    • Users have to configure command set protocols ethernet-oam interface <interface-name> remote-loopback supported on the responding end to enable reactions to loopback control OAMPDUs from peers.

NOTEs:

  • The commands ethernet-oam remote-loopback start interface and ethernet-oam remote-loopback stop interface are operational mode commands which should be executed under the prompt “admin@PICOS>”.

  • Before starting the EFM OAM remote loopback tests:

    • The EFM OAM connection has been established successfully.

    • Users have to configure command set protocols ethernet-oam interface <interface-name> remote-loopback supported on the responding end to enable reactions to loopback control OAMPDUs from peers.

c) Verify the Configuration.

  • After successfully configuring EFM remote loopback, run the command run show ethernet-oam, and you can see that the loopback status is local loopback on Switch C and remote loopback on Switch A.

  • View the statistics information of EFM OAMPDU packets, we can see the number of received Loopback Control OAMPDU packet is 1 on Switch C.

Step 3        Stop EFM remote loopback.

Step 4        Verify the Configuration.

  • Run the command run show ethernet-oam, and you can see that the loopback status is no loopback on Switch C and Switch A.

  • View the statistics information of EFM OAMPDU packets, we can see the number of received Loopback Control OAMPDU packet is 2 on Switch C.