Configuration Notes and Constraints of ERPS
Configuration Notes and Constraints of ERPS
When configuring ERPS, consider the following points:
- A maximum of eight ERPS rings (including both major ring and sub-ring) are supported on a device, and a maximum of two instances can be configured for each ring.
- The ERPS port must be a trunk port.
- Before enabling ERPS, users need to disable spanning tree protocol on specific port.
- Traffic from VLANs other than the control VLAN or data VLAN will be dropped by the ERPS ports.
- Make sure that the control VLAN and data VLANs of an ERPS ring have all been added to the MSTP instance (ERPS protected-instance) and VLAN
- When the ERPS ring instance is enabled, the traffic of MSTP instance 0 will be blocked.
- Control VLAN should be assigned as a tagged VLAN.
- Different ERPS ring instances cannot use the same control VLAN.
- The same control VLAN must be configured for all devices in the same ERPS ring instance.
- To ensure the fast convergence of ERPS, it is recommended not to configure the intersecting link as an RPL link in the configuration of the intersecting ring.
- ERPS only works with MSTP, but not STP/RSTP/PVST.
- MLAG configuration on ERPS ring ports is not supported.
- On such deployments, where gateways are serving VLANs across the ring, VRRP is recommended.
, multiple selections available,
Related content
Configuration Notes and Constraints of ERPS
Configuration Notes and Constraints of ERPS
More like this
Configuration Notes and Constraints of ERPS
Configuration Notes and Constraints of ERPS
More like this
Configuration Notes and Constraints of ERPS
Configuration Notes and Constraints of ERPS
More like this
Configuration Notes and Constraints of ERPS
Configuration Notes and Constraints of ERPS
More like this
Configuration Notes and Constraints of ERPS
Configuration Notes and Constraints of ERPS
More like this
Example for Configuring ERPS
Example for Configuring ERPS
More like this
Copyright © 2025 Pica8 Inc. All Rights Reserved.