System LED Definition:
Label | Detailed Description | Comment |
System LED | - Solid Green – Operating
- Blinking Green – Booting or System in Diagnostic mode
- Solid Amber – Critical Alarm
- Off – Power is Disconnected
| At front side |
Power LED | - Solid Green –2 Power Suppliers are supplied to the switch & operating normally
- Solid Amber –Booting or Single power supplier is installed/operating.
- Blinking Amber –2 Power Suppliers are installed, but only single power supply is operating.
- Off – Power is Disconnected.
| At front side |
FAN LED | - Solid Green – FAN operating normally.
- Solid Amber – A FAN or more failed
| At front side |
Note: For FAN LED, when one of FAN LEDs on the rear side failed, fan led on the front panel will display Amber
QSFP28 port LEDs:
LED | Detailed Description |
Link/ACT LED | - OFF –No link is established on the port.
- Solid Green – A valid link is established as 100GE on the port.
- Solid Amber – A valid link is established as 40GE on the port.
- Solid Blue – A valid link is established as 25GE on the port. (Through break out cable)
- Solid Purple –A valid link is established as 10GE on the port. (Through break out cable)
- Blinking LED – Packets transmission or reception is occurring
|
SFP28 port LEDs:
LED | Detailed Description |
Link/ACT LED | - OFF –No link is established
- Two LEDs / Port Solid Green – A valid 25G link is established
- Solid Yellow – A valid 10G link is established
- Blinking LED – Packets transmission or reception is occurring
|
OOB Management Ethernet port LEDs:
LED | Detailed Description |
Link LED | - Solid Green = Port linked operating at max port speed, i.e. if auto-negotiated/forced to 1G mode
- Solid Amber = Port linked operating at lower speed, i.e. if auto-negotiated/forced to 10/100M on this port
- Off = No Link
|
Activity | - Flashing Green (~30ms) = Port Activity
- Off = No activity
|