set protocols ospf6 timers lsa min-arrival

Run the command set protocols ospf6 timers lsa min-arrival to set the minimum delay in receiving a new version of an LSA. The value of this parameter is in milliseconds and ranges from 0 to 600000.

Run the command delete protocols ospf6 timers lsa min-arrival to remove this configuration and go back to default delay of 1000 milliseconds.


Command Syntax

set protocols ospf6 [vrf <vrf-name>] timers lsa min-arrival <milliseconds>

delete protocols ospf6 [vrf <vrf-name>] timers lsa min-arrival <milliseconds>


Parameter

Parameter

Description

vrf <vrf-name>

Optional. Specifies the name of the VRF for the OSPF instance.

min-arrival <milliseconds>Specify the minimum delay in receiving a new LSA in milliseconds. The value is an integer that ranges from 0 to 600000.

Example

  •  Configure OSPFv3 minimum delay to receive LSA to 2000 milliseconds.
admin@XorPlus# set protocols ospf6 timers lsa min-arrival 2000
admin@Xorplus# commit

Copyright © 2024 Pica8 Inc. All Rights Reserved.