The  maximum entries of OpenFlow Flows is often a critical piece of any SDN solution. This is a summary of Openflow Flow scalability per family of Chipset. 

Chipset

ICAP (maximum entries in default or match modes)

ECAP
(entries)

VCAP
(entries)

L2 (maximum entries when buffer-mode is 5)

L3 (maximum entries when buffer-mode 5)

default

IPv4

IPv6

MAC

ARP

IPv4 host route

IPv4 forwarding  route

IPv6 host route

IPv6 forwarding  route

Helix4

2048

4096

2048

4096

2048

512

1024

32768

16384

6000

8192

3000

Trident2

2048

4096

2048

4096

4096

512

512

32768

12000

12000

6000

6000

Trident2+

8192

16384

8192

16384

16384

512

512

32768

12000

12000

6000

6000

Trident3-X3

3072

3072

3072

3072

3072

512

1024

16384

12000

4000

6000

2000

Trident3-X5

3072

3072

3072

3072

3072

1024

512

32768

12000

12000

6000

6000

Trident3-X7

3072

3072

3072

3072

3072

1024

512

32768

12000

12000

6000

6000

Tomahawk/Tomahawk+

1024

3072

1024

3072

3072

512

512

8192

6500

12000

3250

6000

Tomahawk2

1024

3072

1024

3072

3072

512

512

8192

6500

12000

3250

6000

Maverick

4096

8192

4096

8192

8192

512

512

32768

4000

12000

2000

6000

Tomahawk3

1024

3072

1024

3072

3072

256

256

8192

16384

3840

8192

1920

Trident4-X9

4096

4096

4096

4096

4096

1024

512

163840

12000

3072

6000

1536

 

 

 