In-band Management Interface

In-band Management Interface


Warning:

The command set system inband enable true is obsolete and replaced by command set system inband vlan-interface <vlan-interface>.

By default, the user cannot remotely log in and manage the switch through an L3 VLAN interface. You need to enable the in-band management function by setting set system inband vlan-interface <vlan-interface> to perform the SSH, TELNET, SNMP and HTTP services through any one of the L3 VLAN interfaces in the default VRF.

For example,

Set the L3 VLAN interface VLAN400 in the default VRF as the in-band management port.

admin@Xorplus# set system inband vlan-interface VLAN400
admin@Xorplus# commit

In-band management provides a method of access to the switch even if the Ethernet0/1 interface is down.

NOTE:

  • Only the L3 VLAN interface in the default VRF can be set as the in-band management port. If a VLAN interface has been set as an in-band management port, it can stay in the default VRF, but cannot be bound to other user-defined VRFs.
  • A maximum of four L3 VLAN interfaces in the default VRF can be set as the in-band management ports by using set system inband vlan-interface <vlan-interface> command.


 

 