System LED Definition
Feature | Detailed Description | Comment |
System LED | Solid green – all functions are normal. Flashing Green – Booting Solid Amber –Major Fault. Indicates summary of all major faults within the system; the faults are traffic affecting. Flashing Amber –Minor Fault: Indicates summary of all minor faults within the system; the faults are not traffic affecting. | At front side |
Power LED | Solid Green – Normal. Solid Amber – POST in progress. Flashing Amber – Power supply fault. Off – No power. | At front side |
FAN LED | Solid Green – all functions are normal. Solid Amber –Any Fan tray fault. | At front side |
Beacon LED | Not in use. | At front side |
Stacking LED | Not in use. | At front side |
7-DIGIT Stack LED | Not in use. | At front side |
Â
Port LED Definition
2.5G/5G/10GBase-T Copper Ethernet Port LEDs
Feature | Detailed Description |
LINK/SPD LED (Left bi-color LED) | l Solid Green – Link at 10GBase-T (Max) l Solid Amber – Link at 10/100/1000MBase-T or 2.5/5/10GBase-T l Off – No Link |
ACT/POE LED (Right bi-color LED) | l Blinking Green (~30ms) – Activity, PoE Power Off (Activity for Non-P) l Blinking Amber (~30ms) – Activity, PoE Power On l Solid Amber – No Activity, PoE Power On l Off –No Activity, PoE Power Off |
Â
25GbE SFP28 Port LEDs
Feature | Detailed Description |
LINK/SPD LED (Left bi-color LED) | l Off – No Link l Solid Green –Link at 25GE Speed l Solid Amber –Link at lower than 25GE Speed |
ACT LED (Right bi-color LED) | l Off – No Activity l Blinking Green (~30ms) – Activity |
Â
Stacking (QSFP28) Port LEDs
Feature | Detailed Description |
LINK/ACT LED (Bi-color LED) | - 1st LED: Green/Amber
- Solid Green = Port linked operating at max port speed, i.e. running 100GbE on QSFP28 port. Green (Luminance at 1.5ft = 45+5 cd/m2)
- Flash Green (~30ms) = Port Activity operating at max port speed, i.e. running 100GbE on QSFP28 port. Green (Luminance at 1.5ft = 45+5 cd/m2)
- Solid Amber = Port linked operating at lower speed, i.e. running 40GbE or 25GbE or 10GbE on QSFP28 port. Amber (Luminance at 1.5ft = 45+5 cd/m2)
- Flashing Amber (~30ms) =Port Activity operating at lower speed, i.e. running 40GbE or 25GbE or 10GbE on QSFP28 port. Amber (Luminance at 1.5ft = 45+5 cd/m2)
- Off = No link
- Flashing Amber with 1 sec on and 1 sec off – Port Beacon.  Amber (Luminance at 1.5ft = 180+10 cd/m2)
- All four LEDs shall be used when 4x25GbE mode or 4x10GbE mode is running on QSFP28 port.
- Solid Green = 4x25GbE Link on QSFP28 port. Green (Luminance at 1.5ft = 45+5 cd/m2)
- Solid Amber = 4x10GbE Link on QSFP28 port. Amber (Luminance at 1.5ft = 45+5 cd/m2)
- Flashing (~30ms) Green = 4x25GbE Activity on QSFP28 port. Green (Luminance at 1.5ft = 45+5 cd/m2)
- Flashing (~30ms) Amber = 4x10GbE Activity on QSFP28 port. Amber (Luminance at 1.5ft = 45+5cd/m2)
- Off = No link
- Flashing Amber with 1 sec on and 1 sec off – Port Beacon. Amber (Luminance at 1.5ft = 180+10 cd/m2)
|
Â
OOB Ethernet Port LEDs
Feature | Detailed Description |
Link/SPD LED (Left bi-color LED) | l Off – No Link l Solid Green – Link at 1000Base-T l Solid Amber – Link at 10/100MBase-T |
ACT LED (Right single color LED) | l Off – No Link l Blinking Green (~30ms) – Activity |
Â
Console Port LEDs
Feature | Detailed Description |
Link/SPD LED (Left bi-color LED) | l Off – No Link l Solid Green – Link |