set protocols ospf timers lsa min-arrival

set protocols ospf timers lsa min-arrival

Run the command  set protocols ospf timers lsa min-arrival to set the minimum delay in receiving a new version of an LSA. The value of this parameter is in milliseconds and ranges from 0 to 600000. The optional parameter vrf can be used to specify a VRF for the OSPF instance. If a VRF is not specified here, the command will affect OSPF for the default VRF.

Run the command delete protocols ospf timers lsa min-arrival to remove this configuration and go back to default delay of 1000 milliseconds.


Command Syntax

set protocols ospf [vrf <vrf-name>] timers lsa min-arrival <0-600000>

delete protocols ospf [vrf <vrf-name>] timers lsa min-arrival <0-600000>


Parameter

Parameter

Description

vrf <vrf-name>

Optional. Specifies the name of the VRF for the OSPF instance.

min-arrival <0-600000>Specify the minimum delay in receiving a new LSA in milliseconds. The value is an integer that ranges from 0 to 600000.

Example

  •  Configure OSPF minimum delay to receive LSA to 2000 milliseconds.
admin@XorPlus# set protocols ospf vrf BLUE timers lsa min-arrival 2000
admin@Xorplus# commit