ethernet-oam remote-loopback start|stop interface

The ethernet-oam remote-loopback start interface command starts EFM OAM remote loopback tests on the specific port. The EFM OAM remote loopback control OAMPDU will be sent to the peering device to trigger a remote loopback.

The ethernet-oam remote-loopback stop interface command stops EFM OAM remote loopback tests on the specific port. The EFM OAM remote loopback control OAMPDU will be sent to the peering device to stop a remote loopback.

 

Command Syntax

ethernet-oam remote-loopback start interface <interface-name>

ethernet-oam remote-loopback stop interface <interface-name>

 

Parameter

Parameter

Description

interface <interface-name>

Specifies an interface name. The value could be a physical interface, for example, ge-1/1/1, xe-1/1/2, and so on.

 

Usage Guidelines

When configuring this command, pay attention to the following notes:

  • The commands ethernet-oam remote-loopback start interface and ethernet-oam remote-loopback stop interface are operational mode commands which should be executed under the prompt “admin@PICOS>”.

  • Only the active mode end can run these two commands to start or stop EFM OAM remote loopback tests.

  • Before starting the EFM OAM remote loopback tests, make sure:

    • The EFM OAM connection has been established successfully.

    • Users have to configure command set protocols ethernet-oam interface <interface-name> remote-loopback supported on the responding end to enable reactions to loopback control OAMPDUs from peers.

  • EFM OAM remote loopback tests will fail if above conditions are not met. After all of the conditions are met, you need to execute the command ethernet-oam remote-loopback start interface <interface-name> again to start EFM OAM remote loopback tests again.

  • When remote loopback function is implemented, the interface no longer participates in any other Layer 2 or Layer 3 protocols.

  • When the remote loopback test is completed, you should use the command ethernet-oam remote-loopback stop interface to disable EFM OAM remote loopback tests on the port.

  • It is not allowed to modify the EFM OAM mode when remote loopback function is implementing.

  • The device sends a Loopback Control OAMPDU to the peer when run command ethernet-oam remote-loopback start interface <interface-name> or ethernet-oam remote-loopback stop interface <interface-name>.

 

Example

  • Start EFM OAM remote loopback tests on the specific port.

admin@PICOS> ethernet-oam remote-loopback start interface te-1/1/1
  • Stop EFM OAM remote loopback tests on the specific port.

admin@PICOS> ethernet-oam remote-loopback stop interface te-1/1/1

 