S5860-24XB-U Switch
System LED Definition
LED Name | Status | Detailed Description |
System LED | OFF | No power supply. |
Blinking green | Boot-up in progress. | |
Solid green | The system completes initialization and works normally. | |
Solid amber |
| |
Solid red |
A. Board voltage abnormalities.
| |
Blinking red | A. Long pressing the reset button, it will flash green for the first 5S, and then flash red until the information is collected and the whole machine is reset. | |
FAN LED | Solid green | System FAN operating normally. |
Solid red |
A. Model does not match system
| |
PS LED | OFF | Power supply not present. |
Solid green | This power is operating normally. | |
Solid red | A. Power module failure, no output of 12V, 54V C. Cannot read the model number of the power supply module. | |
MGMT LED | OFF | No Link. |
Solid green | Port linked operating at 1000M. | |
Solid amber | Port linked operating at 10M or 100M. | |
Flashing | Transmit/Receive is activity. | |
PoE LED (controlled by PoE button on the front panel) | Solid green | Port LEDs indicate data switching status. |
Solid amber | Port LEDs indicate PoE power supply status. |
Port LED Definition
RJ45 100M/1G/2.5G/5G/10G port LED
Feature | Detailed Description |
Non-PoE (controlled by PoE button on the front panel) |
|
PoE (controlled by PoE button on the front panel) |
|
SFP+ 10G port LED
Feature | Detailed Description |
SFP+ 10G port LED |
|
SFP28 25G port LED
Feature | Detailed Description |
SFP28 25G port LED |
|