set protocols bfd profile echo receive-interval



The set protocols bfd profile echo receive-interval command configures the minimum time interval between received BFD echo packets for a profile.

The delete protocols bfd profile echo receive-interval command sets the configuration to the default value.


Command Syntax

set protocols bfd profile <profile-name> echo receive-interval [<receive-interval> | disabled]


Parameter

Parameter

Description

profile <profile-name>

Specifies the profile name. The value is a string.

echo receive-interva [<receive-interval> | disabled]

Specifies the minimum time interval between received BFD echo packets in milliseconds. The value disabled indicates that the switch does not support reception of BFD echo packets. Range: 10 to 60000. Default: 50ms.


Example

  • Configure the minimum time interval between received BFD echo packets to 60 milliseconds.
admin@Xorplus# set protocols bfd profile p2 echo receive-interval 60
admin@Xorplus# commit

Copyright © 2024 Pica8 Inc. All Rights Reserved.